Critical Protection for High-Value Infrastructure
Water and coolant piping are integral to modern building systems, especially in data centres and mission-critical facilities. While precision cooling is essential for maintaining operational performance, it also introduces the risk of accidental leaks that may result in equipment damage, service disruption, or costly downtime.
Reliable Components & Seamless Integration
A properly designed water leak detection system provides early warning of leaks, enabling facility teams to respond quickly and minimise operational risk. Tracetek leak detection solutions deliver continuous monitoring and accurate leak location to protect critical assets.
of leak detection cable installed.
| check_circle |
Server Rooms |
| check_circle |
Archival Storage |
| check_circle |
Cooling Systems |
| check_circle |
Office Pantry |
| check_circle |
Racked Equipment |
| check_circle |
Diesel Generators |
Tracetek Leak Detection Modules

| TOUCH SCREEN PANEL |
TT-TS12 |
| The TraceTek TT-TS12 Touch Screen Panel provides a graphic user interface to manage and display information from a network of up to 250 external leak detection system circuits. |
| MORE INFORMATION |

| LEAK DETECTION MODULE |
TTSIM-PLUS |
| An integrated solution designed for server rooms of all sizes, able to monitor up to 150m (500ft) of sensor cable. Features lockable enclosure for added security and damage resistance. |
| ENQUIRE |

| LEAK DETECTION MODULE |
TTDM-128 |
| The TTDM-128 monitors up to 1500m (5000ft) of sensor cable and up to 128 remote TraceTek modules. With its networking capability, the TTDM-128 provides flexibility in terms of layout and monitoring capacity. |
| MORE INFORMATION |

| SENSOR INTERFACE MODULE |
TTSIM-1 |
| The TTSIM-1 monitors up to 1500m (5000ft) of sensing cable and communicates to a range of host systems. An economical choice for builds that require several independent sensing cable segments. |
| MORE INFORMATION |

| SENSOR INTERFACE MODULE |
TTSIM-1A |
| Monitors up to 1500m (5000ft) of TraceTek sensing cable. The TTSIM-1A communicates directly to a PLC or host systems using standard protocols such as the TTDM-128. |
| MORE INFORMATION |

| SENSOR INTERFACE MODULE |
TTSIM-2 |
| The TraceTek TTSIM-2 is able to monitor up to 150m (500ft) of sensor cable. It can be used as a stand-alone leak detection alarm unit, or integrated with the TTSIM, TT-NRM, TTDM-128, or TT-TS12 modules. |
| MORE INFORMATION |

| SENSING MODULE |
TTC-1 |
| The TraceTek TTC-1 offers a low cost option for liquid leak detection. Designed for use with any TraceTek sensing cable. Flexible integration into various systems. Includes three sets of relay contacts that can be used for remote annunciation and equipment control. |
| MORE INFORMATION |

| LEAK DETECTION PROBE |
TT-FLAT PROBE |
| The TT-FLAT PROBE is a special purpose probe designed to detect water leaks in specific, inaccessible locations such as low spots or drip trays. It is designed to be integrated as a part of a larger leak detection system, monitored by controllers such as the TT-SIM module. |
| MORE INFORMATION |

| FAST FUEL SENSOR |
TT-FFS |
| The TraceTek FFS is designed to detect hydrocarbon fuel floating on water, spreading on a surface or collecting in a sump. FM 7745 Standard approved version available for improving safety of diesel generators, oil storage tanks and other equipment. |
| MORE INFORMATION |

| ALARM MODULE |
ZD-18+ |
| The ZD-18+ ALARM MODULE is sed for leak detection in small computer rooms or technical service areas. Allows immediate detection of conductive (water, acid & alkaline) or non-conductive (hydrocarbon fuel or organic solvent) by applying different type of liquid sensing cables. |
| MORE INFORMATION |

| SENSING CABLE |
TT1000 |
| TraceTek TT1000 sensing cables detect the presence of water at any point along their length. Installed with a TraceTek alarm and locating module, the cable senses water intrusion, triggers an alarm, and pinpoints the location. |
| MORE INFORMATION |

| SENSING CABLE |
TT1100-OHP |
| The TraceTek TT1100-OHP water sensing cable is intended for inaccessible areas such as the bottom of a suspended or rack mounted pipe. With an added layer of braided fiber, the TT1100-OHP is fortified against possible contamination. |
| MORE INFORMATION |

| SENSING CABLE |
TT3000 |
| TraceTek TT3000 sensing cable detects the presence of conductive liquids at any point along its length. Most acids, bases and even deionized water can be sensed and located. To be installed with a TraceTek alarm and locating module. |
| MORE INFORMATION |

| SENSING CABLE |
TT5000 |
| The TraceTek TT5000 sensing cables detect the presence of liquid hydrocarbon fuels at any point along its length, yet does not react to the presence of water. Conductive-polymer technology make the TT5000 sensing cable mechanically strong and chemically resistant. |
| MORE INFORMATION |

| SENSING CABLE |
TT5000-HS |
| The TraceTek TT5000-HS sensing cables detect the presence of liquid hydrocarbon fuels without reacting to the presence of water. Specifically protected by a glossy polyethylene outer layer to withstand underground exposure to ground water and various soil conditions. |
| MORE INFORMATION |

| CABLE ID TAG |
TT-TAG |
| The TraceTek TT-TAG are highly visible, contrasting black on yellow tags for sensing cable identification and mapping. |
| MORE INFORMATION |

| MODULAR LEADER CABLE |
TT-MLC |
| The TraceTek Modular Leader Cable connects alarm module to sensing cable. One end is prepared for easy attachment to TraceTek alarm modules while the other end is compatible with sensing cables or, if required, modular jumper cables. |
| MORE INFORMATION |

| MODULAR JUMPER CABLE |
TT-MJC |
| The TraceTek Modular Jumper Cable bridges the connection over certain distances between the TraceTek Leader Cable and sensing cables. Available in modular lengths with plastic or metal connector options. |
| MORE INFORMATION |

| END TERMINATIONS |
TT-MET |
| The TraceTek TT-MET-MC are modular pin/socket end terminations for leak detection sensing cables. Available in plastic or metal connector options. |